Important XIS events for data analysis

2015


2015-05-30 07:23:44 -- 2015-05-30 09:04:32

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.




2015-04-04 08:04:16 -- 2015-04-04 09:45:36

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.



2015-03-22 03:50:56 -- 2015-03-22 14:17:36

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.



2015-03-12 03:14:08 -- 2015-03-12 04:45:52

        XIS3 CCD-T changed.
        This change may be related to the operation of the turning-on of XIS0 and XIS1.




2015-03-05 18:31

        XIS 0, 1 OFF



2015-02-28 01:58:56 -- 2015-02-28 03:40:48

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.





2015-02-23 14:45:20 -- 2015-02-23 14:54:24

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -92.2deg. The sensor may have had different gain and background.





2015-02-12 10:25:04 -- 2015-02-12 12:06:24

        Temperature anomaly in XIS2 CCD-T.





2015-02-03 21:13

        XIS 0, 1, 3 ON





2015-02-03 17:50:56 -- 2015-02-03 20:50:40

        XIS3 CCD-T changed. But this change may be related to the operation of the turning-on of XIS0 and XIS1.





2015-01-30 18:20

        XIS 0, 1 OFF




2015-01-28 00:30

        XIS 0, 1, 3 ON




2015-01-10 20:55 

        XIS 0, 1, 3 OFF due to UVC/over temperature of BAT




2015-01-06 13:20 

        XIS 0, 1, 3 ON




2015-01-03 07:59 

        XIS 0, 1, 3 OFF due to UVC



2014





2014-12-27 17:00 

        XIS 0, 1, 3 ON




2014-12-24 08:16 

        XIS 0, 1, 3 OFF due to UVC




2014-12-22 21:25:20  -- 2014-12-23 19:38:40

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -95.6deg. The sensor may have had different gain and background.





2014-12-20 14:30:24  -- 2014-12-20 16:11:12

        Temperature anomaly in XIS1 CCD-T.
        The actual CCD-T was probably -96.3deg. The sensor may have had different gain and background.





2014-12-05 22:29:52 -- 2014-11-06 00:20:48(?)

        Temperature anomaly in XIS0 CCD-T.
        The end of the anomaly was not clear, since there were no QL HK data. The actual CCD-T was probably lower than -90deg. The sensor may have had different gain and background.





2014-11-28 09:10 

        XIS 0, 1, 3 ON




2014-11-28 07:10 

        XIS 0, 1, 3 OFF




2014-11-27 21:17 

        XIS 0, 1 OFF



2014-11-08 08:53:20 -- 2014-11-08 10:35:12

        Temperature anomaly in XIS3 CCD-T.
        Probably no significant impact on the data, since it is considered that this actually reflects the temperature of XIS2 CCD.




2014-11-05 22:49:04 -- 2014-11-06 00:20:48

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -95.6deg. The sensor may have had different gain and background.





2014-10-24 18:25:04 -- 2014-10-24 20:06:24

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.





2014-10-22 01:42:24 -- 2014-07-15 23:47:44

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -61.7deg. The sensor may have had different gain and background.





2014-10-01 03:48:16 -- 2014-10-01 05:30:40

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.




2014-09-17 18:50 

        XIS 0, 1, 3 ON





2014-09-04 00:11 

        XIS OFF due to UVC




2014-09-03 02:28 

        XIS 0, 1, 3 ON




2014-08-28 04:27 

        XIS OFF due to UVC


2014-08-24 00:07:28 -- 2014-08-24 01:48:16

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.



2014-08-08 16:17:36 -- 2014-08-08 17:57:20

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.



2014-08-03 18:50:40 -- 2014-08-03 20:30:24

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2014-07-28 11:26:24 -- 2014-07-28 13:09:20

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2014-07-21 22:45:52 -- 2014-07-22 00:24:32

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.




2014-07-15 22:06:24 -- 2014-07-15 23:47:44

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -100deg. The sensor may have had different gain and background.



2014-07-10 22:56:32 -- 2014-07-11 00:37:52

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.




2014-06-29 11:02:56 -- 2014-06-29 12:41:36

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -100deg. The sensor may have had different gain and background.




2014-06-26 09:53:04 -- 2014-06-26 11:33:20

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -100deg. The sensor may have had different gain and background.



2014-06-26 08:11:12 -- 2014-06-26 09:53:04

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.



2014-06-26 11:33:20 -- 2014-06-26 13:12:00

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2014-07-03 10:54

        Back to XIS 0,1, and 3 observations. The latter half of ABELL_98-NORTH (seq_no 809078020) were observed with XIS0,1,3.




2014-07-01 05:10 

        XIS 0,1 were terminetad. The Cep X-4 (seq_no 909001010) and the former half of ABELL_98-NORTH (seq_no 809078010) were observed with XIS3 only.




2014-06-20 00:52 -- 2014-06-20 07:30 

        Unexpected observation mode 
        Impact on ObsID 508011020




2014-06-18 20:30 -- 2014-06-19 07:40 

        Unexpected observation mode 
        Impact on ObsID 409037010



2014-05-27 05:35 -- 2014-06-24 16:50 

        Possible incorrect light leak amounts for XIS 1
        Possible impacts on ObsIDs from 809063010 to 809026010



2014-05-27 05:35 

        XIS 0,3 ON



2014-05-20 03:20 

        XIS 1 ON



2014-05-15 20:26 

        XIS OFF due to UVC



2014-05-08 12:37:20 -- 2014-05-08 14:16:32

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2014-04-05 19:32:48 -- 2014-04-05 21:15:12

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.






2014-04-05 04:08:32 -- 2014-04-05 05:47:44

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.





2014-03-01 23:32:16  -- 2014-03-03 19:49:52

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.






2014-02-21 17:17:20 -- 2014-02-21 18:59:44

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.




2014-01-13 20:46:56 -- 2014-01-13 22:59:44

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.




2014-01-08 18:05:52 -- 2014-01-08 19:47:44

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.




2013




2013-12-15 05:53:36 -- 2013-12-04 20:41:36

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.




2013-12-04 19:03:28 -- 2013-12-04 20:41:36

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.




2013-12-01 11:05:36 -- 2013-12-01 12:47:28

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.





2013-11-21 00:16:32 -- 2013-11-21 01:55:44

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.






2013-11-04 04:08:32 -- 2013-11-04 05:50:24

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.




2013-10-24 15:32:48 -- 2013-10-24 17:09:52

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.




2013-10-20 12:44:48 -- 2013-10-20 14:25:04


        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.









2013-10-14 17:40
        XIS was restarted and all operational sensors (including XIS0 segments A and B) came back to observation.

2013-10-12 18:20

	XIS0 segment A amd B did not go back to the 5x5 editing mode after dark frame dump during an SAA passage.
	The reason is unknown. The data in the segments were corrupted until the recovery.

2013-10-09 21:35

        XIS is back to observation.

2013-10-06 17:33

        XIS telemetry was discontinued for unknown reasons during an SAA passage.
	The HK and science data became unavailable. 




2013-09-30 16:50:40 -- 2013-09-30 18:32:00

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.





2013-08-20 14:40:00 -- 2013-08-20 16:21:20

        Temperature anomaly in XIS1 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.






2013-08-07 08:53:20 -- 2013-08-07 19:33:20

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.




2013-08-03 07:52:32 -- 2013-08-03 09:30:08

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.




2013-07-13 10:21:20 -- 2013-07-13 12:02:08

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.





2013-07-11 08:52:48 -- 2013-07-11 10:34:40

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.





2013-07-05 22:57:36 -- 2013-07-06 00:32:00

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.





2013-06-28 15:25:20 -- 2013-06-28 17:06:40

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -72deg. The sensor may have had different gain and background.







2013-06-22 17:46:08 -- 2013-06-22 19:27:28

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.







2013-06-14 03:14:08 -- 2013-06-14 04:54:24

        Temperature anomaly in XIS1 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.






2013-06-09 03:46:40 -- 2013-06-09 05:27:28

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.





2013-06-07 05:41:20 -- 2013-06-07 07:22:08

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -95deg. The sensor may have had different gain and background.






2013-05-18 18:01:04 -- 2013-05-18 19:40:16

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.




2013-04-13 09:41:20 -- 2013-04-13 11:22:08

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.



2013-04-08 XIS3 failed to execute the P-sum observation for Cyg X-1 (sequence number 407015010) due to an operation mistake. The two other sensors were operative. The observation was recovered in next month after fixing the problem (407015020).

2013-03-25 02:45:52 -- 2013-03-25 13:20:32

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.




2013-03-22 22:05:20 -- 2013-03-22 23:44:00

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.





2013-02-28 15:20:32 -- 2013-03-01 02:00:00

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.







2013-02-12 19:29:36  -- 2013-02-13 17:48:48

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -95deg. The sensor may have had different gain and background.






2013-01-30 15:06:08 -- 2013-01-30 16:48:32

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.




2013-01-21 00:34:40 -- 2013-01-21 02:14:24

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.





2013-01-14 23:25:52 -- 2013-01-15 01:08:16

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.






2012



2012-12-24 20:44:16  -- 2012-12-25 19:02:56

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.




2012-12-04 20:20:16 -- 2012-12-04 22:02:08

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.




2012-11-22 06:00:00 -- 2012-11-22 07:41:52

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2012-11-14 05:01:52 -- 2012-11-14 06:44:16

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.




2012-11-06 19:14:08 -- 2012-11-06 20:53:52

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -94deg. The sensor may have had different gain and background.



2012-10-16 05:39:12 -- 2012-10-16 07:18:56

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2012-10-04 05:03:28 -- 2012-10-04 06:45:20

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2012-08-01 15:13:36 -- 2012-08-01 16:54:24

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.



2012-07-30 10:17:04 -- 2012-07-30 11:59:28

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2012-07-16 18:10:40 -- 2012-07-16 19:52:32

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2012-07-11 21:25 -- 2012-07-14 01:50 

	XIS observation terminated during the RCS operation of the satellite.
	The TEC2 for the XIS2 was terminated permanently for power saving.

2012-06-30 04:00:32 -- 2012-06-30 05:41:52

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.




2012-06-21 11:29:36 -- 2012-06-21 13:09:20

        Temperature anomaly in XIS1 CCD-T.
        The actual CCD-T was probably -69deg. The sensor probably had different gain and background.



2012-05-12 04:13:52 -- 2012-05-12 05:53:04

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.



2012-05-07 02:54:24 -- 2012-05-07 04:36:16

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -94deg. The sensor may have had different gain and background.



2012-04-20 19:24:16 -- 2012-04-20 21:03:28

        Temperature anomaly in XIS1 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.



2012-03-01 01:58:24 -- 2012-03-01 12:37:52

        Temperature anomaly in XIS1 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.



2012-02-01 07:37:04 -- 2012-02-01 09:18:56

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.





2012-01-26 15:25

	The XIS was restarted after the UVC of the satellite.
	Themo-electric control for XIS2 was terminated to save power consumption.



2012-01-15 17:13:36 -- 2012-01-15 18:53:52

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -92deg. The sensor may have had different gain and background.




2011


2011-12-21 01:41:20 -- 2011-12-21 03:21:04

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.


2011-12-07 16:02:40  -- 2011-12-07 17:41:20

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.


2011-11-30 09:46:40 -- 2011-11-30 11:28:00

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.


2011-11-20 20:32:32 -- 2011-11-20 23:51:28

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.


2011-11-18 18:57:04 -- 2011-11-18 20:39:28

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.


2011-11-14 01:58:56 -- 2011-11-14 03:38:40

        Temperature anomaly in XIS1 CCD-T.
        The actual CCD-T was probably -93deg. The sensor may have had different gain and background.




2011-11-08 21:13:36 -- 2011-11-08 22:54:56

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -94deg. The sensor may have had different gain and background.



2011-10-24 06:35:12 -- 2011-10-24 08:16:32

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.





2011-10-15 02:10 -- 2011-10-15 13:04
	E0102-72_1_4_WIN was observed with 1/8win mode due to an operation mistake.




2011-10-12 22:14:56 -- 2011-10-13 08:51:44

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.




2011-10-03 16:09:04 -- 2011-10-03 17:50:24

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2011-09-29

	The PPU ration among the three operating sensors (XIS0, 1, and 3) was changed.
	The telemetry saturation limit was increased by 10 % or more.



2011-09-23 18:20:48 -- 2011-09-23 20:03:12

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.





2011-09-16 06:34:40 -- 2011-09-16 08:14:24

        Temperature anomaly in XIS1 CCD-T.
        The actual CCD-T was probably -67deg. The sensor probably had different gain and background.





2011-09-14 10:09:00 -- 2011-09-15 10:50:00 

	The MAXI_J_1836-194 observation was conducted with a wrong DAC setting in XIS1.
	It uses a micro-code for CI=2 keV, while the actual amount of CI was set to be 6 keV.
	Users need to use the response file for CI=6 keV.




2011-09-11 06:53:20 -- 2011-09-11 08:32:00

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -69deg or so. The sensor probably had different gain and background.





2011-09-01 05:45

        The charge injection acmount of XIS1 (Normal, 0.1s burst option) was increased to improve the high energy response.
	The data taken after this event requre a new RMF.




2011-08-27 12:40:32 -- 2011-08-27 14:22:24

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.




2011-08-26 07:38:08 -- 2011-08-26 09:20:00

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -94deg or so. The sensor may have had slightly different gain and background.





2011-08-23 05:38

        The charge injection acmount of XIS1 (Normal, 1/4 window option) was increased to improve the high energy response.
	The data taken after this event requre a new RMF.


2011-08-15 18:20:16 -- 2011-08-15 20:02:08

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.




2011-08-10 23:38:08 -- 2011-08-11 01:17:20

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -95deg or so. The sensor may have had slightly different gain and background.




2011-08-09 01:24:48 -- 2011-08-09 03:04:00

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.




2011-07-31 00:11:12 -- 2011-07-31 01:52:32

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.




2011-07-26 11:53 - 2011-07-27 12:26 (PERSEUS_CI_2 06006010)

	The amount of injection charges was decreased for the XIS1 for calibration purposes.
	The data are uncalibrated and should not be used for scientific purposes.



2011-07-22 14:00:00 -- 2011-07-23 00:33:04

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.




2011-07-16 12:43:12 -- 2011-07-16 14:22:24

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.




2011-07-07 13:10:56 -- 2011-07-07 14:52:48

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2011-06-21 15:36:32 -- 2011-06-21 17:18:56

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.





2011-06-01 11:15

        The charge injection acmount of XIS1 (Normal, no option) was increased to improve the high energy response.
	The data taken after this event requre a new RMF.




2011-05-07 00:12:16 -- 2011-05-07 01:52:32

        Temperature anomaly in XIS1 CCD-T.
        The actual CCD-T was probably -92deg or so. The sensor may have had slightly different gain and background.



2011-04-25 21:21:36 -- 2011-04-25 23:03:28

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2011-04-09 13:17:52 -- 2011-04-09 14:57:36

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -59.5deg or so. The sensor probably had different gain and background.




2011-04-04 06:46:56 -- 2011-04-04 08:29:20

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -62.0deg or so. The sensor probably had different gain and background.




2011-03-14 16:08:32 -- 2011-03-14 17:49:20

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -91deg or so. The sensor may have had slightly different gain and background.






2011-03-11 03:10

        XIS is back to observation.

2011-03-09 02:15:45

        XIS MPU is halted by NMI (Non-Maskable Interrupt) during an SAA passage.
	The watch-dog timer in the onboard MPU program is usually reset by an interrupt
	from the DP I/F board, but this did not properly work for one time, causing a 
	watch-dog time out. The event seems a single event, and we do not observe the same
	event to repeat.





2011-03-08 07:32:48 -- 2011-03-08 09:07:44

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -60deg or so. The sensor probably had different gain and background.




2011-04-25 11:19 - 2011-04-26 01:58 (N132D 106010010)
2011-04-11 19:34 - 2011-04-12 08:27 (E0102-72_CI_6 106002010)
2011-02-22 04:59 - 2011-02-23 04:30 (PERSEUS_CI_6 105027010)
2011-02-21 17:40 - 2011-02-22 04:59 (PERSEUS_1_4_WIN_CI_6 105028010)

	The amount of injection charges was increased for the XIS1 for tests and calibration.
	The data are uncalibrated and should not be used for scientific purposes.
	The data are recognized by the file name "ae*xi1_0_NxNn069u_cl.evt".


2011-02-09 20:29:20 -- 2011-02-09 22:03:44

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -94deg or so. The sensor may have had slightly different gain and background.



2011-01-03 13:17:52 -- 2011-01-03 14:54:56

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.

2010



2010-12-16 17:26:56 -- 2010-12-16 19:06:40

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.



2010-10-28 00:02:40 -- 2010-10-28 01:34:24

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.



2010-10-21 00:23:28 -- 2010-10-21 02:03:44

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -93deg or so. The sensor may have had slightly different gain and background.




2010-10-15 17:50:24 -- 2010-10-15 19:32:48

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -64deg or so. The sensor probably have had different gain and background.




2010-10-07 00:57:04 -- 2010-10-07 02:38:56

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.



2010-09-18 08:25:36 -- 2010-09-18 10:08:00

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -93deg or so. The sensor may have had different gain and background.


2010-09-18 15:11:28 -- 2010-09-18 16:50:40

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.


2010-09-12 10:20:48 -- 2010-09-12 12:02:08

        Temperature anomaly in XIS3 CCD-T.
        The actual CCD-T was probably -95deg or so. The sensor may have had different gain and background.

2010-09-07 15:36:32 -- 2010-09-07 17:18:24

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.

2010-08-06 08:03:12 -- 2010-08-06 09:45:04

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.

2010-08-05 04:41:36 -- 2010-08-05 06:23:28

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.
       

2010-07-23 18:41:36 -- 2010-07-23 20:21:20

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.
       
2010-07-23 13:37:36 -- 2010-07-23 15:18:56

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.
       
2010-07-19 23:50:56 -- 2010-07-20 01:27:28

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.
       


2010-12-23 01:07 - 2010-12-23 03:28 (CYGNUS_LOOP_P8_CI_2 105007030)
2010-12-22 22:47 - 2010-12-23 01:07 (CYGNUS_LOOP_P8_CI_6 105007020)
2010-12-07 18:59 - 2010-12-09 00:36 (E0102_PSUM 105006020)
2010-10-26 19:15 - 2010-10-27 07:43 (E0102 105004050)
2010-08-29 18:12 - 2010-08-30 21:19 (E0102_PSUM 105006030)
2010-08-09 09:02 - 2010-08-10 00:15 (PERSEUS 105009010)
2010-06-20 07:26 - 2010-06-21 12:29 (E0102_PSUM 105006010)
2010-06-11 05:36 - 2010-06-11 05:50 (CYGNUS_LOOP_P8 105007010)

	The amount of injection charges were increased for the XIS1 for tests and calibration.
	The data are uncalibrated and should not be used for scientific purposes.
	The data are recognized by the file name "ae*xi1_0_NxNn069u_cl.evt".




2010-06-18 14:32:00 - 2010-06-18 16:10:40

        Temperature anomaly in XIS0 CCD-T.
        The actual CCD-T was probably -68deg or so. The sensor probably had different gain and background.



2010-06-09 19:55:12 - 2010-06-09 21:30:40

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.

2010 6/7 11:39:27 - 20:03:13
	During the observation of A133_N and A133_W, the erroneous dark frame
	problem occurred in all the sensors. The event data in 
	RAWY < 119 were affected by this problem.  
	See this page for the detail of this symptom.

2010-06-01 13:30:40 -- 2010-06-01 15:12:32

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.


2010-05-23 03:21:04 -- 2010-05-23 04:58:40

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.

2010-05-07 09:01:52 -- 2010-05-07 10:41:36

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.


2010-04-05 20:19:12 -- 2010-04-05 22:01:04

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.




2010-03-23 11:50:24 -- 2010-03-23 22:26:40

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2010-03-13 05:36:00 -- 2010-03-13 07:16:48

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2010-03-04 14:21:52 -- 2010-03-04 16:02:08

        Temperature anomaly in XIS0 SNK-T.
        No significant impact on the data.



2010-02-25 12:53:20 -- 2010-02-25 14:35:12

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2010-02-18 04:11:12 -- 2010-02-18 14:49:04

        Temperature anomaly in XIS1 CCD-T.
        The actual temperature was probably at -92.5deg or so. The sensor might have slightly different gain and background.


2010-02-02 08:16:00 -- 2010-02-02 09:55:12

        Temperature anomaly in XIS1 SNK-T.
        No significant impact on the data.



2010-01-27 05:07:44 -- 2010-01-27 06:49:36

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.



2010-01-12 12:22:56 -- 2010-01-12 14:04:48

        Temperature anomaly in XIS3 SNK-T.
        No significant impact on the data.


2009

12/18 XIS1 anomaly. See this suzaku memo for detail.

11/26 10:00 - 18:00

	XIS CPU program update. No XIS data can be used for scientific purposes.

10/12 4:00-10/14 12:10
	After a diagnostic operation of XIS0, the senor failed to go back to
	observation. Resultantly, XIS0 was unoperational during the period 
	above. Other sensors (XIS1 and 3) were in operation, but their dark 
	levels may be inproperly estimated until 10/14 10:30. Users are advised
	not to use data during this period without a consultation to the XIS team.

7/6 10:37:09 - 7/7 05:27:29
	During the observation of TT Ari, the erroneous dark frame
	problem occurred in all the sensors. The event data in 
	RAWY < 119 were affected by this problem.  
	See this page for the detail of this symptom.

6/23 - 9/7, 10/12
	Diagnostic operations for XIS0 were occasionally performed.
	XIS0 data obtained during this period might include some frames
	for diagnostic purposes, which should be removed for data
	reduction by general users.

6/27 16:30
	The area discrimination (RAWX=70-150) is applied for all the data
	obtained from this time onward, which masks most of the fake events
	due to the leak current in the XIS0 segment A.

6/23 2:00

	An anomaly occurred in XIS0. A part of the XIS0 segment A was 
	suddenly flooded by a large amount of leak current, leaving an 
	unrecoverable damage to the XIS0.
	In the Normal clocking mode, a part of the XIS0 segment A 
	(RAWX=70-150) became dysfunctional. In some data, spurious events 
	appear around RAWY=1024 in the remaining part of the segment A. 
	No significant change in the detector response is found. 
	However, users need to take a special care to reduce data taken by
	XIS0 segment A in the Normal clocking mode after the event.

	In the Psum clocking mode, the effect reaches to the entire XIS0 
	sensor. All data taken in the Psum clocking mode after the event 
	are inappropriate for any scientific use.

5/18 8:22 - 10:04
	Temperature anomaly in XIS0.
       The CCD temperature increased up to -60 degC, although the
       HK data showed an incorrect value of -90 degC.
       The XIS0 data in this period are not usable because
       large amount of the dark current filled the telemetry
       with the false events.

4/13 5:46 - 7:26
	Temperature anomaly in XIS0.
       The CCD temperature decreased down to -93 degC, although the
       HK data showed an incorrect value around -51 degC.
       No significant impact on the data, but the sensor might have
       slightly different gain.

2/18 2:03 - 3:44
	Temperature anomaly in XIS0.
       The CCD temperature decreased down to -93 degC, although the
       HK data showed an incorrect value around -77 degC.
       No significant impact on the data, but the sensor might have
       slightly different gain.

2008


12/6 19:12 - 20:51
	Temperature anomaly in XIS0.
       The CCD temperature decreased down to -93 degC, although the
       HK data showed an incorrect value around -50 degC.
       No significant impact on the data, but the sensor might have
       slightly different gain.

10/27 9:55 - 11:37
	Temperature anomaly in XIS0.
       The CCD temperature decreased down to -93 degC, although the
       HK data showed an incorrect value around -78 degC.
       No significant impact on the data, but the sensor might have
       slightly different gain.

9/18 15:43 - 9/19 2:13
	Temperature anomaly in XIS3.
       The CCD temperature decreased down to -93 degC, although the
       HK data showed no apparent change.
       No significant impact on the data, but the sensor might have
       slightly different gain.

9/10 7:36 - 9:18
	Temperature anomaly in XIS0.
       The CCD temperature decreased down to -93 degC, although the
       HK data showed an incorrect value around -81 degC.
       No significant impact on the data, but the sensor might have
       slightly different gain.

8/1 5:05 - 6:45
	Temperature anomaly in XIS0.
       The CCD temperature decreased down to -93 degC, although the
       HK data showed an incorrect value around -45 degC.
       No significant impact on the data, but the sensor might have
       slightly different gain.

4/21 14:05 - 15:46
	Temperature anomaly in XIS0.
       The CCD temperature decreased down to -93 degC, although the
       HK data showed an incorrect value around -46 degC.
       No significant impact on the data, but the sensor might have
       slightly different gain.

2/22 11:40 - 20:30
           When Suzaku started to observe IGRJ17391-3021, illegal
           commands were issued to the XIS due to a mistake in operation.
           This resulted in an incorrect onboard dark estimation, and the 
           data obtained before 2008-02-22 20:30(UT) cannot be used.

1/30 18:55 - 2/6 04:50
           Trouble in the CPU board of the XIS data processing unit. 
           No XIS data usable for scientific purpose were produced
           in this period.   XIS was restarted using the backup
           CPU board and resumed the observations.

2007

12/23 02:53-04:29
           Temperature anomaly in XIS1.
           The CCD temperature increased up to -65 degC, although the
           HK data showed an incorrect value around -94 degC.
           The XIS1 data in this period are not usable because
           large amount of the dark current filled the telemetry
           with the false events.

12/19 23:40 - 12/20 1:19
           Temperature anomaly in XIS0.
           The CCD temperature decreased down to -93 degC, although the
           HK data showed an incorrect value around -76 degC.
           No significant impact on the data, but the sensor might have
           slightly different gain.

12/8 4:48 - 12/12 0:30
           Trouble in the on-board data processing of XIS0.
           No usable data were output for Segments C & D of XIS0.
           The HK data were also invalid for these segments.
           The trouble was caused by the bit-upset due to energetic
           particles in SAA in one of the data processing units of XIS0.

11/5 21:08 - 22:48
           Temperature anomaly in XIS0.
           The CCD temperature increased up to -59 degC, although the
           HK data showed an incorrect value around -116 degC.
           The XIS0 data in this period are not usable due to the
           large increase of the thermal noise.

10/29 7:18 - 17:56
           Temperature anomaly in XIS1.
           The CCD temperature decreased down to -93 degC, although the
           HK data showed an incorrect value around -83 degC.
           No significant impact on the data, but the sensor might have
           slightly different gain.

10/8 11:24 - 13:03
           Temperature anomaly in XIS0.
           The CCD temperature decreased down to -94 degC, although the
           HK data showed an incorrect value around -78 degC.
           No significant impact on the data, but the sensor might have
           slightly different gain.

8/17 16:25 - 8/28 14:46
           Temperature anomaly in XIS1.
           The CCD temperature decreased down to -93 degC, although the
           HK data showed an incorrect value around -65 degC.
           No significant impact on the data, but the sensor might have
           slightly different gain.

7/20 2:40 - 4:19
           Temperature anomaly in XIS1.
           The CCD temperature decreased down to -93 degC, although the
           HK data showed an incorrect value around -84 degC.
           No significant impact on the data, but the sensor might have
           slightly different gain.

6/22 10:06 - 11:48
           Temperature anomaly in XIS0.
           The CCD temperature increased up to -58 degC, although the
           HK data showed an incorrect value around -115 degC.
           The XIS0 data in this period may have significantly different
           performance in terms of the dark current, energy resolution
           and the gain.

4/8 21:45 - 23:29
           Temperature anomaly in XIS3.
           The CCD temperature decreased down to -92 degC, although the
           HK data showed an incorrect value around -52 degC.
           No significant impact on the data, but the sensor might have
           slightly different gain.

4/8 6:13 - 7:53
           Temperature anomaly in XIS0.
           The CCD temperature increased up to -62 degC, although the
           HK data showed an incorrect value around -113 degC.
           The XIS0 data in this period may have significantly different
           performance in terms of the dark current, energy resolution
           and the gain.

3/31 23:53 - 4/1 1:02
           Abnormally large number of events in XIS0 segment A possibly 
           due to the light-leak estimation error.

3/29 21:56 - 3/30 1:10
           Abnormally large number of events in XIS0 segment D possibly 
           due to the light-leak estimation error.

3/5 3:12 - 13:47
           Temperature anomaly in XIS3.
           The CCD temperature decreased down to -93 degC, although the
           HK data showed an incorrect value around -62 degC.
           No significant impact on the data, but the sensor might have
           slightly different gain.

2/15 18:13 - 20:42  
           Abnormally large number of events in some sensors/segments
           possibly due to the light leak estimation error.
           Errors were found in the following intervals:
		XIS0, segment A: 18:13 - 20:42
		XIS3, segment C: 19:19 - 20:42
		XIS3, segment D: 18:52 - 20:42

1/10 18:06 - 19:48
           Temperature anomaly in XIS2.  
           The CCD temperature decreased down to -94 degC, although the HK 
           data showed an incorrect value around -44 degC.  No significant 
           impact on the data, but the sensor might have slightly 
           different gain.

2006

12/20 10:37
           XIS telemetry allocation ratio was changed from 3:3:3:3 to 3:3:1:3
           (XIS0:XIS1:XIS2:XIS3).

12/13 3:50-4:04
           Increase of the XIS event rates (up to 800 cnts/8sec/segment)
           possibly due to the solar flare (X3.4) occurred at 2:14.

12/6 19:20-19:30
           Increase of the XIS event rates (up to 200 cnts/8sec/segment)
           possible due to the solar flare (X6.5) occurred at 18:29.

12/5 15:13 - 16:54
           Temperature anomaly in XIS0.
           The CCD temperature increased up to -57 degC, although the HK 
           value indicated an incorrect temperature of -116 degC. The XIS0 
           data in this period may not be usable due to the significantly
           different performance and the telemetry saturation.

12/5 10:25 - 10:35
           XIS event rates increased up to 10^3 cnts/8s/segment probably 
           due to the large solar flare (X9.0) occurred at 10:18.
           Similar but moderate increases of the event rates were observed
           during the satellite day time on the same day.

11/22 11:03 - 11/23 2:10
           A burst option was mistakenly applied to XIS0 and XIS3.

11/20 17:12 - 18:54
           Temperature anomaly in XIS0.  
           The CCD temperature decreased down to -94 degC, although the HK 
           data showed an incorrect value around -64 degC.  No significant 
           impact on the data, but the sensor might have slightly 
           different gain.

11/17 2:20 - 4:05
           No XIS1 data due to an operation error.

11/9 1:04:15
           Anomaly occurred in XIS2. 
           Large amount of extra charge flooded the CCD.
           Hereafter, XIS2 became unusable.

11/9 1:56 - 3:37
           Temperature anomaly in XIS1.  
           The CCD temperature increased up to -63 degC, although the HK 
           value indicated an incorrect temperature of -257 degC. The XIS1 
           data in this period may have significantly different performance
           in terms of the dark current, energy resolution and the gain.

11/7 7:38 - 11/8 7:45
           Temperature anomaly in XIS0.  
           The CCD temperature decreased down to -94 degC, although the HK 
           data showed an incorrect value around -52 degC.  No significant 
           impact on the data, but the sensor might have slightly 
           different gain.

10/27 8:58 - 10:40
           Temperature anomaly in XIS3.   The CCD temperature increased
           up to -54 degC, although the HK data incorrectly showed the nominal 
           value of -90 degC.    The XIS2 data in this period may have
           significantly different performance in terms of the energy 
           resolution and the gain.

9/21 7:41 - 9:21
           Temperature anomaly in XIS0.   CCD temperature decreased
           down to -94 degC, although the HK data showed incorrect value
           around -47 degC.    No significant impact on the data, 
           but the sensor might have slightly different gain.

7/31 23:40 - 8/1 3:20
           No data in FI sensors.   FI sensors stayed in the standby mode
           due to the error in the mode change sequence.

7/23 11:59 - 13:39
           Temperature anomaly in XIS2.   CCD temperature decreased
           down to -91 degC, although the HK data showed incorrect value
           around -56 degC.    No significant impact on the data, 
           but the sensor might have slightly different gain.

6/29 5:09 - 15:49
           Temperature anomaly in XIS2.   CCD temperature decreased
           down to -93 degC, although the HK data showed incorrect value
           around -40 degC.    No significant impact on the data, 
           but the sensor might have slightly different gain.

6/16 2:16 - 3:57
           Temperature anomaly in XIS3.   CCD temperature decreased
           down to -93 degC, although the HK data showed incorrect value
           around -70 degC.    No significant impact on the data, 
           but the sensor might have slightly different gain.

6/7 5:48 - 7:31
           Temperature anomaly in XIS2.   The CCD temperature increased
           up to -74 degC, although the HK data showed an incorrect value 
           around -102 degC.    The XIS2 data in this period may have
           significantly different performance in terms of the energy 
           resolution and the gain.

5/11 18:09 - 19:51
           Temperature anomaly in XIS1.   CCD temperature decreased
           down to -92 degC, although the HK data showed incorrect value
           around -45 degC.    No significant impact on the data, 
           but the sensor might have slightly different gain.

5/11 16:27 - 18:10
           Temperature anomaly in XIS0.   CCD temperature decreased
           down to -92 degC, although the HK data showed incorrect value
           around -77 degC.    No significant impact on the data, 
           but the sensor might have slightly different gain.

4/20 13:05 - 14:41
           Temperature anomaly in XIS2. The CCD temperature increased
           up to -80 degC, although the HK data incorrectly showed the nominal
           temperature of -90 degC. The XIS2 data in this period may have
           significantly different performance in terms of the energy 
           resolution and the gain.

3/29 20:13 - 23:11
           No XIS FI (S0,S2,S3) data. 
           The sensors stayed in the standby mode due to the operation error.

3/15 2:18 - 3:02
           XIS1 light leak error.   Light leak estimation became incorrect 
           during the micro-code upload.   XIS1 data in this period may not 
           be usable.

3/10 5:45 - 6:30
           XIS1 light leak error.   During the recovery operation from 
           the temperature anomaly mentioned above, light leak estimation 
           became incorrect.   XIS1 data in this period may not be usable.

3/10 5:06 - 5:45
           Temperature anomaly in XIS1.   CCD temperature decreased
           down to -92 degC, although the HK data showed incorrect value
           around -45 degC.    No significant impact on the data, 
           but the sensor might have slightly different gain.

2/17 22:12  
           Event threshold of FI sensors was changed to 100 adu.

2/17 13:56 - 15:37
           Temperature anomaly in XIS1   CCD temperature decreased
           down to -92 degC, although the HK data showed incorrect value
           around -84 degC.    No significant impact on the data, 
           but the sensor might have slightly different gain.

2/13 16:15
           Soft current limit of TEC was reduced to 92% to avoid excess 
           thermal stress to the XIS heat sink assembly.  After this, 
           CCD temperature might show temporary excursion of a few 
           degrees, which has no impact on the data quality.

2/8 15:02
           Event threshold of FI sensors was changed to 60 adu.

2/2 12:42 - 19:50
           No XIS data due to the bug in the microcode.

1/18 2:50 - 1/20 8:00
           XIS on-board software update.   Data obtained in this period
           may or may not be usable for scientific analysis.    After this
           software update, G7-equivalent grades were rejected on board.
           Light-leak estimation regions were changed from 64x64 to 
           256x113(114).   Event threshold of FI sensors was changed from
           100 adu to 50 adu.

1/5 5:49 - 7:31
           Temperature anomaly in XIS1.   CCD temperature decreased
           down to -93 degC, although the HK data showed incorrect value
           between -65 - -74 degC.    No significant impact on the data, 
           but the sensor might have slightly different gain.

2005


12/06 6:55 - 7:16
           Charge injection.   Many pseudo-events were telemetered.

11/27 1:04 - 2:46
           Temperature anomaly in XIS1.   CCD temperature decreased
           down to -92 degC, although the HK data showed incorrect value
           between -81 - -88 degC.    No significant impact on the data, 
           but the sensor might have slightly different gain.

11/22 14:33 - 11/23 2:48
           Temperature anomaly in XIS0.   CCD temperature decreased
           below -90 degC, although the HK data showed incorrect value
           of -83 degC.    The data may be usable, but the sensor might
           have slightly different gain.

10/21 22:45 - 10/22 1:30
           Timing mode with no line summation.
           This was a test operation and no scientific data were acquired.

10/21 21:05-21:25
           Charge injection.   Many pseudo-events were telemetered.

10/17 0:15-2:00
           XIS1 operation error due to the bug of the microcode.

10/4 8:24 - 10:09
           Temperature anomaly in XIS0.   The CCD temperature increased
           up to -70 degC, although the HK data showed incorrect value
           of -104 degC.    The XIS0 data in this period may have significantly
           different performance in terms of the energy resolution and the gain.

9/4 4:55 - 15:39
           Temperature anomaly in XIS0.   CCD temperature decreased below 
           -90 degC, although the HK data showed incorrect value of -80 degC.
           This may have been caused by the incorrect self-calibration of the 
           ADC due to the particle event just after the SAA passage.   The data 
           may be usable, but the sensor might have slightly different gain.

8/29 2:20 - 2:26
           Charge injection.   Large number of pseudo-events were telemetered.

8/19 4:10 - 9:14
           Error in light-leak estimation.
           Size of the light-leak regions was increased from 64x64 to
           256x256, which caused an error in the light-leak estimation.
           The size was set back to 64x64 at 8/19 9:14.
           Data from all the sensors in this period are not usable.

8/13 6:00  XIS-S2 door open.
     7:40  XIS-S1 door open.
     9:20  XIS-S0 door open.

8/12 7:41  XIS-S3 door open.